Search Search all

Chiller 4 kw – Water Chillers Factory

ClassificationIndustry News 256

Chiller 4 kw – Water Chillers Factory

 

The installation of the 4 kw chiller is a very important thing. But many users tend to ignore the importance of installation. In fact, the chiller cannot be installed in any environment. It also needs to meet the basic installation conditions to ensure the normal and stable operation of the chiller. If the installation is not good, it may affect the use effect of the industrial chiller. The following will introduce the installation method and installation instructions of the chiller.

Installation method of 4 kw chiller:

1. Open the package and check whether the chiller is in good condition and whether the accessories are complete.

2. Confirm that the 4 kw chiller is properly grounded.

3. Select a water pipe with a suitable diameter (recommended specification: silicone tube 8 x 14 mm), connect the accessory water connector to the water pipe correctly and fix it with a cable tie, and insert it into the water outlet and the water return port.

4. Make sure that the air inlet and outlet channels of the chiller are smooth, and do not put foreign objects into the equipment.

5. The water flow should remain stable under any load conditions.

6. To protect the circulating water pump, it is strictly forbidden to run without water.

7. In order to reduce noise and vibration, it is better to install a vibration isolator on the pipeline.

Installation instructions for 4 kw chiller:

1. In the location selected for installation, the chiller should be installed on a stable level surface and should be as close as possible to the cooled machine.

2. The chiller is suitable for installation in an indoor environment. The ambient temperature is preferably between 8°C and 35°C, and the relative humidity does not exceed 80%. If possible, the 4 kw chiller should be installed near a site with a proper drainage system to prevent stagnation due to leaks.

3. Do not install in places with corrosive gas, humidity, excessive dust or high room temperature.

4. The installation position of the chiller should not be close to the wall on all sides. Leave a space of more than 0.8 meters on the hot air discharge side and more than 0.5 meters on the side. The room must be fully ventilated, and the air intake must be slightly greater than the exhaust air volume of the 4 kw chiller, or Use an air conditioner with cooling capacity greater than heat consumption to cool down.

 

Customized Solutions For Your Business


low temperature chiller

Low Temperature Chillers (Custom Designs)

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series-110°C ~ -50°C series -150°C ~ -110°C series
Cooling Capacityup to 360kWup to 360kWup to 360kWup to 270kWup to 180kWup to 11kW

 


recirculating chiller

Recirculating Chillers (Custom Designs)

Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacityup to 38kWup to 12kWup to 7.2kWup to 7.2kWup to 8.6kW

 


water chiller

Room Temperature Chillers / Small Chillers (Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacityup to 0.9kWup to 50kW

 


Direct Cooling machine

 

Direct Cooling Type Refrigeration Equipments (Custom Designs)

It is suitable for places with small heat exchange area and large heat exchange.

 

Temperature range -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
Compressor Powerup to 8HPup to 8HP*2up to 45HP*3

 


Chillers for Automotive Battery Test (Custom Designs)

Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc.

 

Temperature range -25°C ~ +100°C -40°C ~ +100°C0°C ~ +100°C  -40°C ~ +135°C
Cooling Capacityup to 38kWup to 60kWup to 60kWup to 60kW

 

Temperature / Pressure / Flow can be independently controlled.

1&2: one machine for two groups control.

Temperature range -40 ~ +100℃ 1&20 ~ +100℃ 1&2
Cooling Capacityup to 60kW*2up to 60kW*2

 

Temperature remains constant, pressure / flow can be independently controlled.

1&3: one machine for three groups control.

1&6: one machine for six groups control.

Temperature range -40 ~ +100℃ 1&2 -40 ~ +100℃ 1&3 -40 ~ +100℃ 1&6 -20 ~ +100℃ 1&6 0 ~ +100℃ 1&2 0 ~ +100℃ 1&3 0 ~ +100℃ 1&6
Cooling Capacityup to 60kWup to 60kWup to 60kWup to 60kWup to 60kWup to 60kWup to 60kW

 


Semiconductor Chillers (TES series) (Custom Designs)

Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.

Temperature range -45°C ~ +250°C series -85°C ~ +200°C series -60°C ~ +200°C series
Cooling Capacityup to 25kWup to 25kWup to 60kW

 


Semiconductor Chillers (LTS series) (Custom Designs)

Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.

Temperature range -20°C ~ +80°C series -45°C ~ +80°C series -60°C ~ +80°C series -80°C ~ +80°C series
Flow Control7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


 

Chillers for Energy Storage(Custom Designs)

Liquid Cooling Solutions For Battery Energy Storage Systems

 

 

 

Temperature range -45°C ~ +55°C
Cooling Capacityup to 45kW

 


screw-chillers

 

Screw Chillers (Custom Designs)

Low temperature screw chillers and room temperature screw chillers

 

 

Temperature range +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Cooling Capacityup to 1027kW (Single Compressor)up to 2134kW (Dual Compressor)up to 934kW (Single Compressor)up to 1940kW (Dual Compressor)up to 467kW (Single Compressor)up to 497kW (Single Compressor)

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller