Search Search all

Best Heater Cooler

ClassificationIndustry News 307

Best Heater Cooler

 

Best heater cooler is a cooling and heating temperature control device that can provide cold or heat sources. It can realize cooling and heating functions during the production process to meet the temperature control requirements of different occasions.

First, best heater cooler application industry

1. Pharmaceutical and chemical industry: often supporting reactors, reactors, distillation, extraction, mixing equipment, pressure vessels, drying, etc. for cooling, heating and temperature control;

2. Components industry: used to test various components, chips, and integrated circuits at different temperatures;

3. New energy industry: conduct temperature control tests at different temperatures on new energy batteries and motors.

Second, the operating instructions of the best heater cooler

1. Best heater coolers are used in different industries, but the temperature ranges required by different reactions are different. If a single refrigeration or heating device is used for temperature control, it will occupy more space and cost. This best heater cooler can Manually adjust different temperature ranges to meet temperature requirements.

2. When selecting the heat transfer medium, do not use water as the heat conduction medium. Unsuitable heat transfer medium will have a negative impact on the best heater cooler and may cause damage to the device.

3. Only use the heat transfer medium specified by the manufacturer and use it within the specified pressure range. Pay attention to its temperature limit and lower limit, combustion, viscosity, freezing point, etc., and whether it is suitable for the internal piping of the instrument when transferring heat. Select the middle tube, the length should be as short as possible, and the diameter should be as short as possible.

4. The best heater cooler needs to reset the equipment adjustment parameters after filling, which is the correct operation and use required by the instrument.

5. The heat conduction medium pipeline of best heater cooler cannot be knotted, and the heat medium pipe should be checked regularly to avoid material strain.

6. Pay attention to the pipeline when using it. In order to avoid the pipeline of the best heater cooler, when using water-cooled equipment, please use water treatment chemicals to clean the pipeline dirt regularly when using water with high mineral content.

7. The best heater cooler can linearly control the temperature of the material that needs to be exothermic or heated or refrigerated during the reaction process. You can choose a program to control the temperature and set the temperature of the material medium. The entire best heater cooler is set with a fully closed circulation pipeline. During the temperature control process, there will be no phenomenon of oil mist absorbing water, which is conducive to improving the efficiency of equipment circulation.

Different production standards of best heater cooler can achieve different ranges of temperature control, and the application range is greatly improved. Best heater cooler is a commonly used temperature control equipment in the industry. It is used in pharmaceutical, chemical, biological and other industries to provide heat and cold sources for reactors, reactors, etc., and can also be used for heating and cooling of other equipment.

 

Customized Solutions For Your Business


Cooling and Heating Systems (SUNDI series)

Temperature Control Range: -120°C to +350°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -40 ~ +200°C series -10 ~ +200°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series -25 ~ +200°C one machine for two reactors -40 ~ +200°C one machine for two reactors
Cooling Capacityup to 3kWup to 15kWup to 200kWup to 200kWup to 200kWup to 25kWup to 60kWup to 25kWup to 15kWup to 80kWup to 80kWup to 80kWup to 10*2kWup to 10*2kW

 


Cooling and Heating Systems (WTD series)

(Micro channel / tube reactors specialized)

Temperature Control Range: -70°C to +300°C

Specialized design for micro channel (small liquid holding capacity, strong heat exchange capacity, circulation system high pressure drop)

 

Temperature range -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Cooling Capacityup to 7.5kWup to 5.5kWup to 50kW

 


Cooling and Heating Systems (TES series)

Temperature Control Range: -85°C ~ +250°C

Temp Control Accuracy: ± 0.3°C

 

 

Temperature range -45°C ~ +250°C series -85°C ~ +200°C series -60°C ~ +200°C series
Cooling Capacityup to 25kWup to 25kWup to 60kW

 


Cooling and Heating Machines (LTS series)

Temperature Control Range: -80°C to +80°C

It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.

 

 

Temperature range -20°C ~ +80°C series -45°C ~ +80°C series -60°C ~ +80°C series -80°C ~ +80°C series
Flow Control7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


Cooling and Heating Circulators

Temperature Control Range: -45°C to +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacityup to 15kWup to 15kW

 


Heating Circulators

Temperature Control Range: +50°C to +300°C

Note: UC series can control the temperature of heat transfer medium. UST series can not only control the temperature of the heat transfer medium, but also control the temperature of the reaction material.

Temperature range +50°C ~ +200°C  (UC series) +50°C ~ +300°C  (UC series) +50°C ~ +300°C  (UST series)
Heating Capacityup to 38kWup to 200kWup to 95kW

 


TCU Multi-reactors Temperature Control System

Temperature Control Range: -120°C to +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -45°C ~ +250°C series -120°C ~ +250°C seriesCustomized Temperature Control SystemRT+10°C ~ +135°C
Heating Capacityup to 80kWup to 80kWCustomup to 300kW

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller