Search Search all

120 Ton Chiller – Water Chiller Supplier

ClassificationIndustry News 236

120 Ton Chiller – Water Chiller Supplier

 

120 ton chiller has many models according to different temperature ranges. It is widely used in low temperature reaction fields in chemical, pharmaceutical, biochemical and other industries. It has fast cooling speed, safety and reliability. After customers purchase 120 ton chiller, the first thing to do is to install the equipment , so which aspect should be paid attention to when installing?

1. The condenser of the 120 ton chiller is a finned type, and a heat dissipation fan is installed on the top of the unit, which directly dissipates heat through the fan to achieve heat exchange effect.

2. Before installing the 120 ton chiller, it is necessary to choose a flat open space where the cement foundation can be laid again to ensure the levelness of the ground. After the installation is completed, there must be free space for future maintenance and to ensure that the ground can withstand 120 ton chiller operating weight. Of course, depending on the model of the equipment, the diameter of the water inlet and outlet is also different. When installing, it is necessary to select a water pipe with a matching diameter and connect it correctly.

3. When the 120 ton chiller is under load, it is necessary to ensure that the water flow of the equipment is normal and stable. The design and installation of all chilled water pipes should be carried out in accordance with relevant standards, and the chilled water pump should be located on the water inlet pipe of the unit to ensure the positive pressure and flow of the unit. The water pump of the 120 ton chiller is installed inside the unit, so a shock-absorbing pipe should be installed when piping to ensure proper elasticity and prevent the water from the evaporator from being drained when the pump stops.

4. The pipeline of the 120 ton chiller should have a firm support independent of the chiller to avoid stress on the components of the chiller. In order to reduce noise and vibration, it is better to be able to install vibration isolators on the pipeline.

5. In order to run the 120 ton chiller safely and stably, to ensure the normal use of each component, the poor water quality can be treated to avoid the accumulation of various sundries or corrosion deposits in the pipeline, evaporator, and condenser to affect the heat exchange effect , increasing maintenance costs in the later period.

 

Customized Solutions For Your Business


 

low temperature chiller

Low Temperature Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -150°C to -5°C

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series -110°C ~ -50°C series
Cooling Capacityup to 360kWup to 360kWup to 360kWup to 270kWup to 180kW

 


recirculating chiller

Recirculating Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -120°C to +30°C

Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacityup to 38kWup to 12kWup to 7.2kWup to 7.2kWup to 8.6kW

 


water chiller

Room Temperature Chillers / Small Chillers

Temperature Control Range: +5°C to +50°C

The chiller can be widely used in various industries and laboratories, and supports customized design.

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacityup to 0.9kWup to 50kW

 


Direct Cooling machine

 

Direct Cooling Type Refrigeration Equipments

Temperature Control Range: -120°C to -10°C

It is suitable for places with small heat exchange area and large heat exchange.

 

Temperature range -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
Compressor Powerup to 8HPup to 8HP*2up to 45HP*3

 


 

Direct Cooling Ultra Low Temp Chillers

Temperature Control Range: -150°C to -110°C

Customized solutions for your business.

 

Temperature range -150°C ~ -110°C
Cooling Capacityup to 11kW

 


screw-chillers

 

Screw Chillers

Low temperature screw chillers and room temperature screw chillers

Customized solutions for your business.

 

 

Temperature range +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Cooling Capacityup to 1027kW (Single Compressor)up to 2134kW (Dual Compressor)up to 934kW (Single Compressor)up to 1940kW (Dual Compressor)up to 467kW (Single Compressor)up to 497kW (Single Compressor)

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller