Search Search all

100 Ton Chiller – Industrial Water Chiller Factory

ClassificationIndustry News 174

100 Ton Chiller – Industrial Water Chiller Factory

 

In summer, many companies need to run chillers 24 hours a day, so the utilization rate is very high. However, after entering autumn and winter, enterprises in some areas no longer need chillers for cooling, but only need to cool through cooling water towers. When the enterprise stops using the 100 ton chiller, it is still necessary to do a good job in the maintenance of the chiller to facilitate the normal operation of the chiller in the next year.

100 ton chiller cleaning steps

1. Turn off the water source of the chiller, and clean up the water inside the equipment components and pipes, so as to avoid the remaining water from corroding the unit components after shutdown, or the temperature is too low to freeze the copper pipes; at the same time, unscrew the drain nut under the water pump to drain the water inside Drain the remaining water to prevent the water system from freezing due to low ambient temperature, the evaporator bursting and causing refrigerant leakage or water pump impeller damage and other failures.

2. Turn off the power of the 100 ton chiller, and check whether each part is worn (if any, it needs to be replaced).

3. Clean the fan of the air-cooled 100 ton chiller and keep it in a clean state.

4. For the water tank of the water tank coil evaporator, check whether there are scales and other debris and remove them.

5. Understand the use of lubricating oil through data records, and regularly replace lubricating oil according to the usage standards to maintain a good lubrication state.

 

Customized Solutions For Your Business


low temperature chiller

 

Low Temperature Chillers (Water Cooled or Air Cooled)

Ultra-low temperature cascade refrigeration technology.

Each temperature segment has more than a dozen product models for you to choose from.

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series -110°C ~ -50°C series -150°C ~ -110°C series
Cooling Capacity3 ~ 103 Ton1.5 ~ 103 Ton1.5 ~ 103 Ton1.1 ~ 77 Ton0.5 ~ 52 Ton0.7 ~ 3.2 Ton

 


recirculating chiller

 

Recirculating Chillers (Water Cooled or Air Cooled)

Closed circulation pipeline, ethylene glycol mixed with water for refrigeration.

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacity0.2 ~ 11 Ton0.1 ~ 3.5 Ton0.1 ~ 2.1 Ton0.05 ~ 2.1 Ton0.08 ~ 2.5 Ton

 


water chiller

 

Room Temperature Chillers / Small Chillers

High-precision refrigeration temperature control system.

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacity0.09 ~ 0.26 Ton0.5 ~ 15 Ton

 


Direct Cooling machine

 

Direct Cooling Type Refrigeration Equipments

It is suitable for places with small heat exchange area and large heat exchange.

Temperature range -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
Compressor Powerup to 8HPup to 8HP*2up to 45HP*3

 


 

Direct Cooling Ultra Low Temp Chillers

The ultra-low temperature direct cooling chiller adopts the secondary subcooling technology, and the cooling speed is fast. The refrigerant in the refrigeration system is directly output and evaporated into the target control element (heat exchanger) for cooling.

Temperature range -150°C ~ -110°C
Cooling Capacityup to 11kW

 

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller